What type of indicator should be used in autoclaving




















Due to the use of pressure, steam and high temperatures, there is significant risk for injury, so it's important for individuals to be properly trained on operational procedures. The reason for autoclaving infectious waste is that it must be handled several times during transport; proper containment and treatment at the source reduces the potential for an accidental exposure.

The necessary treatment to achieve sterility will vary in relation to the volume of material treated, its contamination level, moisture content and other factors.

Contact information and areas of expertise can be found on the Contact Us page. The following are examples of compatible and incompatible materials. This is not an exhaustive list. Important Notice: Autoclaving hazardous materials may generate toxic vapors or explosive environments.

The proper packaging and containment of infectious materials are crucial to achieve effective sterilization. The most frequent reason for sterilization failure is the lack of contact between the steam and microorganisms. Dry material should be separated from liquid material to achieve proper sterilization. Skip to main content. The University of Iowa Search. You are here Home » Biological. Autoclave Compatible and Incompatible Material. Autoclave Compatible and Incompatible Material The following are examples of compatible and incompatible materials.

Compatible Materials Incompatible Materials Biological cultures and stocks Materials containing solvents, volatile or corrosive, or flammable chemicals Culture dishes and related materials Material contaminated with chemotherapeutic agents or cytotoxic drugs Contaminated solid items i.

General Guidelines. Every autoclave and sterilizer should be inspected and serviced on a regular basis. This will help ensure the equipment is functioning properly. Each unit should have a standard operating procedure written in sufficient detail to ensure that operators will use the equipment properly; controls vary between brands, with each having unique loading characteristics, load-sizing requirements, and cycle setting and types.

Units should be tested regularly with a commercial preparation containing Geobacillus stearothermophilus spores a biological indicator , in particular, any unit in a BSL3 facility. Tape indicators autoclave tape with heat sensitive, chemical indicators should be used in every autoclave load.

Note: the indicators only verify that the autoclave has reached normal operating temperatures; they do not indicate that the contents were heated for the appropriate length of time or at the proper pressure. Therefore, tape indicators cannot be used to prove organisms are actually killed during an autoclave run. Keep detailed records on biological tests, recording thermometers, and service work performed on the unit. High density wastes or materials that insulate the agents from heat and steam penetration are not suitable for steam sterilization.

Items that are covered with dirt or film require additional retention times. The importance of properly cleaning items to be sterilized cannot be over emphasized. Place all autoclaved infectious waste into red biohazard bags for disposal.

An online training video was developed by Arizona State University that offers safety information, examples of waste to be autoclaved, and procedures for spore testing that may be helpful to any user. Most bags that are marketed as autoclavable are not suitable if closed because the steam will not penetrate them.

Steam resistant bags must be left open or have holes punched into the top to allow the steam to penetrate. Sterile Processing Department SPD staff should always follow the manufacturer's instructions for use and healthcare compliance organizations' guidelines and requirements when using chemical indicators for sterility assurance monitoring.

Chemical indicators are required when using a steam sterilization process to verify that the critical parameters of the cycle were met. The way chemical indicators are used with an autoclave process depends on the indicator Type and sterilization cycle. Chemical indicators should be used in conjunction with physical monitors and any other appropriate measure of sterility assurance.

What happened to "Class"? The change to "Type" was made to ensure that within the different types of indicators, one wasn't necessarily thought to be better than another.

For example, a Type 5 Chemical Indicator isn't necessarily better than a Type 1, but instead measures different parameters. However, Types 5 and 6 are preferred for internal pack monitoring as they provide the user with more information on critical sterilization parameters. The table below includes the types of chemical indicators, what each type of chemical indicator indicates, and an example of how the chemical indicator may be applied.

Bowie Dick test used to check the efficiency of the air removal and steam penetration within the chamber. Moving front indicators placed inside packs and can be used on a variety of sterilization cycles. Strips placed in packs that respond to and monitor specific cycles i. Healthcare facilities should purchase chemical indicators from a reliable, accessible source for easy reordering.

Chemical Indicators can be purchased from companies that offer sterilization and infection prevention products. Factors that may be considered when deciding which chemical indicators to purchase include sterilization modality being monitored, performance, brand name, cost, range and variety of products, validated applications and ease of use. Refer to ISO for more information on supplier selection. Infection Prevention. Sterile Processing. Surgical Equipment.

Live Chat Email Sign-Up. What are chemical indicators used for? How do chemical indicators work? How are chemical indicators used for sterilization? What are the different types of chemical indicators for sterilization? Where to buy chemical indicators. Where to Buy Chemical Indicators?

Live Chat Share Print. What they Indicate. Application Example. Type 1 Chemical Indicators : Process Indicators.